energymanager.myCheck my building

Guides · Certified energy manager or Registered Energy Manager?

Certified energy manager or Registered Energy Manager: which one the law asks for

The certified energy manager is a US credential; the Registered Energy Manager is on the Energy Commission's register, and only the second meets the Act.

Energy Efficiency and Conservation Act 2024 (Act 861), sections 25 to 29; Energy Efficiency and Conservation Regulations 2024, P.U.(A) 466/2024, regulations 14 and 16 · Checked 26 November 2026 · 15 min read

Two titles sound alike, and only one counts.

Search for “certified energy manager” in Malaysia and you get course sellers, PDFs and brochures. Few of them say which title the Energy Efficiency and Conservation Act 2024 (Act 861) asks for. This page does.

The short answer: if a company needs you as its energy manager under the Act, you need to be a Registered Energy Manager (REM) with the Energy Commission (Suruhanjaya Tenaga). A certified energy manager (CEM) may help you learn the work, but it does not register you.

What is a certified energy manager, and is it the same as an REM?

No. They are two different things.

A certified energy manager (CEM) is a professional credential that the Association of Energy Engineers, a US body, gives after training and an exam. AEE calls it its energy management certification of more than 40 years (aeecenter.org, read 26 Nov 2026). It is not the Energy Commission’s register, and Act 861 does not name it.

Engineers take a training course and an exam, and AEE keeps its own directory of certified professionals and its own renewal rules. The AEE’s CEM page sets those out.

Course sellers in Malaysia offer CEM training, and it is a recognised name around the world.

But Act 861 does not ask for it. Nothing in Act 861 or its Regulations names the CEM. A company that appoints a CEM holder who is not on the register has not appointed an energy manager under the Act.

Why the titles get mixed up

Before 2025, the old electrical energy manager under EMEER 2008 was a third title in the mix. Some search answers still describe that scheme as if it were current. It was repealed on 1 January 2025.

So a search today can turn up three names for what sounds like one job. Only the REM is the title the Act uses now.

Which energy manager title does the EECA actually ask for?

The Registered Energy Manager, and nothing else.

The Act asks for a Registered Energy Manager. Section 25 of Act 861 says no energy manager may carry out the Act’s duties unless registered with the Energy Commission and holding a valid practising certificate. Doing the work without both is an offence with a fine of up to RM20,000 (Act 861, read on st.gov.my 26 Nov 2026).

A site that used 21,600 GJ or more in 12 consecutive months must appoint an REM within 3 months of the Energy Commission’s notice (P.U.(A) 466/2024, regulations 3 and 4). The clock starts on the day the Energy Commission’s notice arrives.

A company that fails to appoint one commits an offence under section 5(3) of the Act, with a fine of up to RM50,000. That is why the REM is the title that matters to an employer under the Act.

CEM REM
Given by Association of Energy Engineers (US) Energy Commission (Malaysia)
What it is A training credential and exam A place on the Commission’s register, plus a practising certificate
Who may hold it Set by AEE Malaysian citizens with the qualifications in regulation 14
Meets the EECA No Yes
Renewal AEE’s own rules Practising certificate renewed every 1 to 3 years, with 16 CDP hours per year
Where to look up a name AEE’s directory The Commission’s list of REMs on MySTEE

What this means for your CV

A CEM sits well beside the REM on a CV. It shows training beyond the minimum. But if a job ad names the EECA, the REM is the line the employer will check first.

Employers can check a name on the Commission’s list. If yours is not there, the CEM does not fill the gap.

What is the difference between a First Type and a Second Type REM?

The site’s yearly energy use decides the type.

The Regulations make two types of REM (regulation 5, P.U.(A) 466/2024). A First Type REM may serve a site using 21,600 GJ up to 50,000 GJ in 12 consecutive months. A Second Type REM may serve any site, and is the only type for a site above 50,000 GJ or for an external appointment.

  • First Type REM: may serve a site using 21,600 GJ up to 50,000 GJ in 12 consecutive months.
  • Second Type REM: may serve any site, and is the only type for a site using more than 50,000 GJ, and the only type a company may hire from outside its own staff (regulation 6).

A worked example in kWh

The Commission counts electricity at 3.6 MJ per kWh, or 0.0036 GJ per kWh. So 21,600 GJ is 6,000,000 kWh a year, or 500,000 kWh a month on average.

The upper line, 50,000 GJ, is about 13,890,000 kWh of electricity alone. A factory using 8,000,000 kWh a year and nothing else is at 28,800 GJ. A First Type REM may serve it.

Natural gas, LPG and the other energy resources in the Act’s First Schedule are added in GJ alongside the electricity. Diesel and petrol are on neither of the Act’s lists, so they are left out of the sum.

How you move up

You start as First Type. To move up, you need at least 1 year as a First Type REM with a valid practising certificate, the Second Type training and assessment, and knowledge of the Act that satisfies the Commission (regulation 14(2); Guide on Registration of Energy Manager, May 2026, paragraph 4.9).

When the Second Type is issued, the Commission marks your First Type certificates as inactive. The Second Type training certificate is also valid for 5 years (paragraph 4.10).

For what a company does with each type, read hiring a Registered Energy Manager.

If you were an electrical energy manager under EMEER 2008

The Efficient Management of Electrical Energy Regulations 2008 were repealed on 1 January 2025, the day the EECA came into force (st.gov.my, EECA 2024 page, read 26 Nov 2026).

A person who still holds a valid electrical energy manager registration under the Electricity Supply Act 1990 may apply to be a Second Type REM by sitting the Commission’s assessment, until that old registration expires (regulation 14(3), P.U.(A) 466/2024).

The old registration does not carry over on its own. You must sit the assessment while it is still valid.

If it has already expired, you take the normal route: First Type training and assessment, then at least 1 year as First Type before moving up. See EMEER 2008 and the EECA.

Who can become a certified energy manager in Malaysia under the Act?

In law, that means who can become an REM.

To be a First Type REM you must be a Malaysian citizen, have no conviction for fraud, dishonesty or corruption, know the Act, and hold a listed qualification, such as a degree in science, engineering, technology or architecture with at least 2 years of work experience (regulation 14(1); Guide on Registration of Energy Manager, May 2026).

The full list of routes, from regulation 14(1) and the Guide, paragraph 4.4:

Qualification Working experience needed
Degree in science, engineering, technology or architecture At least 2 years
Diploma in the same fields At least 10 years
Graduate Engineer or Engineering Technologist (Board of Engineers) At least 2 years
Inspector of Works At least 10 years
Professional Engineer None stated
Graduate Technologist (Technologists and Technicians Act 2015) At least 2 years
Qualified Technician with at least a diploma At least 10 years
Professional Technologist None stated
Graduate Architect (Architects Act 1967) At least 2 years
Professional Architect None stated

What counts as a recognised degree and as experience

The degree or diploma must be one the Commission recognises. That means equivalent to one accredited or recognised by bodies such as the MQA, JPA or MARA (Guide, paragraph 4.7).

Working experience counts only from after the degree, diploma or registration. It must also be relevant to it (paragraph 4.8). Years worked before you graduated do not count.

Training: who must take the course

Every route needs the First Type training course and assessment at a registered training institution. The one exception is a Professional Engineer, who only needs to pass the assessment under the Commission or a registered training institution (Guide, paragraph 4.6).

A training certificate for either type is valid for 5 years from the date the training was completed (paragraphs 4.5 and 4.10). Do not sit the course years before you plan to apply.

How do you register as an REM, step by step?

There are six steps, all set by the Commission.

The Energy Commission’s Guide on Registration of Energy Manager (May 2026) sets six steps: train and pass the assessment, apply on MySTEE with a RM30 fee, answer any request for papers within 14 days, attend an interview if called, pay the issue fees within 14 days, then receive your certificates (read on st.gov.my 26 Nov 2026).

  1. Train and pass the assessment at a registered training institution (or the assessment only, for a Professional Engineer).
  2. Apply online on the Commission’s MySTEE portal, with the documents in the Guide’s appendices, and pay the RM30 application fee.
  3. Review. If anything is missing, the Commission gives you 14 days to send it, or it may decline the application. You can apply again.
  4. Interview, if asked. The Commission may call you, with two weeks’ notice, to an objective or subjective exam and a face-to-face interview. Bring your original documents. Missing two interview sessions means the application is rejected.
  5. Pay the issue fees within 14 days of the approval notice: RM100 for the certificate of registration, RM30 to apply for the practising certificate and RM100 for its issue. Payments are not refunded.
  6. Receive your certificates. The certificate of registration, and a practising certificate valid for 1 year from its date of issue.

The forms and the portal link are on the Commission’s registration page for energy managers and auditors. Questions go to rem@st.gov.my.

What to prepare before you apply

  • Your degree, diploma or professional registration, with proof that the Commission recognises it.
  • Proof of working experience dated after that qualification.
  • Your training certificates of attendance and completion, each with its own identification code, from a registered training institution.
  • Your original documents, ready for an interview.

Common mistakes

  • Paying for a course that is not approved. Only a registered training institution counts. Ask for the approval code and check the course is on the ST Training Calendar.
  • Taking a CEM course and expecting it to register you. It does not.
  • Letting the 5 years run out. A training certificate older than 5 years cannot be used.
  • Counting years from before graduation. They do not count as working experience.
  • Missing the 14 day windows. Late papers or late fees can end the application.

The energy manager training post walks the same route with more on choosing a course.

Hiring rather than training? Check whether your site is over 21,600 GJ first. Add a year of kWh in the converter on the home page. It only needs your bill totals.

How much does it cost to become a registered energy manager?

The Commission’s own fees come to RM260.

A first REM registration costs RM260 in the Commission’s fees: RM30 to apply, RM100 for the certificate of registration, RM30 to apply for the practising certificate and RM100 for its issue (Act 861, sections 27 and 28; P.U.(A) 466/2024, Schedule). Course fees are set by each training institution and are extra.

Item Fee Source
Application for registration RM30 Act 861 s.27(2); Guide, May 2026
Certificate of registration RM100 Act 861 s.27(3)(a)
Application for practising certificate RM30 Act 861 s.28(2)
Issue of practising certificate RM100 Act 861 s.28(3)(a)
First registration, in all RM260
Application to renew practising certificate RM30 Act 861 s.29(3); Regulations, Schedule item 12
Renewal of practising certificate RM100 per year Act 861 s.29(5)(a); Schedule item 13
Late renewal RM100 Act 861 s.29(2); Schedule item 14

A worked example over 3 years

Say you register as a First Type REM and renew once for 2 years. The first registration is RM260. The renewal is RM30 plus RM100 for each of the 2 years, so RM230.

That is RM490 in the Commission’s fees over 3 years, before any course or CDP fees. Renew late and add RM100.

The same RM260 applies again when you register as a Second Type REM. The CEM’s fees are set by AEE, not by the Commission, so they are not in the Regulations.

How do you keep an REM registration: renewal and CDP hours?

Registration is not a one-off.

A practising certificate is renewed online for between 1 and 3 years. Each renewal needs proof of continuous development programmes: 16 CDP hours for each year of renewal, at a registered training institution, with one CDP hour equal to one hour of learning (Guide on Registration of Energy Manager, May 2026, sections 5 and 6).

CDP can be a physical class, an online class, a conference or tracked e-learning. It counts whether you take part as a participant or as a trainer.

How the hours split

Hours from one topic can only be split as the Guide’s examples show. Two 8 hour topics renew for 1 year. Two 16 hour topics renew for up to 2 years. A single 4 hour topic is not enough to renew at all.

A whole topic you do not need this time carries forward to the next renewal. Leftover hours inside a topic you used do not.

An REM who completes the mandatory CDP topics in the Guide’s Appendix 5 may be exempted from submitting CDP for renewal.

Plan the year

Book CDP early in the certificate year, not in the last month. A late renewal costs RM100 more, and an REM without a valid practising certificate may not carry out the Act’s duties (section 25).

What does an energy manager job involve under the Act?

The duties are set in law, not by the employer.

Section 5(2) of Act 861 sets the energy manager’s duties: collect and analyse the site’s energy data, see that an energy management system is in place and followed, prepare the yearly energy efficiency and conservation report and vouch for it, and advise on savings. Failing in them carries a fine of up to RM20,000 (section 5(4)).

The Commission’s Guidelines on Functions and Duties of Registered Energy Manager explain each duty. In the first year, an REM:

  1. Collects at least 12 consecutive months of energy data from before the appointment, then keeps collecting it.
  2. Sets up the energy management system, which the site must have within 1 year of the REM’s first appointment (regulation 8).
  3. Runs Energy Management Committee meetings at least four times a year, and a management review with top management at least once a year.
  4. Works with the Registered Energy Auditor, whose first audit report is due within 1 year of the notice, then every 5 years. See the energy audit.
  5. Writes the yearly report in the Commission’s format, filed 30 days after the first year, then 30 days after each anniversary of the first appointment.

In-house or external jobs

The default is an REM on the company’s own staff (regulation 4(1)). That REM may also serve up to 7 other energy consumers that are related corporations of the company.

An external REM is allowed for up to 3 years from the date of the notice, and must be a Second Type REM (regulation 6). The external REM may serve up to 7 other energy consumers. After 3 years, the site must appoint an REM from its own staff.

So external work needs the Second Type, and in-house jobs open up as each external term ends. For a site’s first weeks after the notice, read the day the notice arrives.

For companies hiring

A company that needs an REM by its deadline can read hiring a Registered Energy Manager. It covers in-house and external appointments and what to ask before you sign.

Where can you read the rules yourself?

Every rule above is on the Commission’s own pages.

The Energy Commission publishes the Act, the Regulations and the Guide on Registration of Energy Manager (May 2026) on st.gov.my, and keeps the list of REMs on MySTEE. Its EECA 2024 page lists the documents; its registration page links the forms and the portal (both read 26 Nov 2026).

All read on 26 November 2026. If a course seller’s brochure says something different from these pages, the Commission’s pages win.

Questions

Does a CEM meet the EECA?

No. The Act asks for a Registered Energy Manager on the Energy Commission's register, with a valid practising certificate (section 25, Act 861). The CEM is a credential of the Association of Energy Engineers, a US body, and does not put anyone on that register.

Where do I apply to be an REM?

Online, through the Energy Commission's MySTEE portal at mystee.st.gov.my. The forms for registering and renewing are linked from st.gov.my/registration-energy-manager-auditor. You apply after passing the REM training course and assessment at a registered training institution, and you pay a RM30 application fee when you submit.

How much does it cost to register as an REM?

RM260 for a first registration: RM30 to apply, RM100 for the certificate, RM30 to apply for the practising certificate and RM100 for its issue. Renewal is RM30 plus RM100 per year, with a RM100 late fee (P.U.(A) 466/2024, Schedule). Training fees are set by each institution and are extra.

Can a Professional Engineer skip the REM training?

A Professional Engineer applying for the First Type only needs to pass the assessment, under the Commission or a registered training institution. Every other route needs the First Type training course and the assessment (Guide on Registration of Energy Manager, May 2026, paragraph 4.6).

I was a Registered Electrical Energy Manager under EMEER 2008. What now?

EMEER 2008 was repealed on 1 January 2025. If your electrical energy manager registration under the Electricity Supply Act 1990 is still valid, you may apply to be a Second Type REM by sitting the Commission's assessment, until that registration expires (regulation 14(3), P.U.(A) 466/2024).

Read next

Does the Act cover my site?Who counts as an energy consumer, how the fuels add up, where the Act applies and what it asks.What changed from the 2008 electricity rule?The old electricity-only rule, the new 21,600 GJ line, old REEM certificates and Sabah's 2024 rule.Hiring a Registered Energy ManagerWhich type your site needs, in-house or outside for up to 3 years, and what to ask before you sign.The energy auditWho may sign it, the 12 parts of the report, the 80% rule and the data to have ready.ESCO contractsGuaranteed or shared savings, how savings are measured, and the 16 firms on the Commission's ESCO register.